UR629 Series Athalon® Return Line Duplex Filters
Description
Athalon® maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity. Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today. (* per ISO 16889)
Notes and Specifications Filter Housing
- Flows to 1500 L/min (400 US gpm)
- Pressures to 28 bar (400 psi)
- Port Size 3” and 4”
- Rated Fatigue Pressure:
0-23 bar (330 psi) per NFPA T2.06.01R2-2001 CAT C/90/* (1 million cycles), verified by testing at 0-27 bar (392 psi) for 1 million cycles. - Filter Element Burst Pressure:
10 bard (150 psid) - Fluid Compatibility:
Compatible with all petroleum oils and most water glycols, water-oil emulsions, and most synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals:
-29˚ C to 120˚ C (-20˚ F to 248˚ F)
60˚ C (140˚ F) maximum in HWCF or water glycol fluids - Bypass Valve Setting:
4.5 bard (65 psid) or
1.7 bard (25 psid) - Indicator Pressure Setting:
3.5 bard (50 psid) or
1.1 bard (16 psid) - Materials of Construction:
Head, tube, manifold and check valve: Aluminium Cover: Cast iron - Filter Element :
Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
Features
- Patented Ultipleat (laid-over pleat) filter medium pack
- Pall Stress-Resistant Technology (SRT) Media
- Coreless filter element configuration
- Low clean differential pressure for low energy operation
Specifications
Dimensional Drawings
Dimensions in mm (inches)
Contact Pall for dimensions for UR669 and UR689 housings.
Length Code |
Overall Length mm (in.) |
Element Removal Clearance mm (in.) |
Empty Weight kg (lb) |
20 | 897.1 (35.32) | 442.7 (17.43) | 88.9 (196) |
40 | 1405.1 (55.32) | 950.7 (37.43) | 112.5 (248) |
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.Housing pressure drop is directly proportional to specific gravity.
- Keeps fluids the cleanest, longest, for the greatest value
- Provides consistent, reliable, protection of system components over the full service life of the filter element
- Rapidly achieves and sustains required fluid system cleanliness
- Delivers maximum filter capacity in the smallest footprint
- Prevents electrostatic discharge from damaging your filter and degrading your fluid
Element Pressure Drop
610 Series Filter Elements – bard/1000 L/min (psid/US gpm)
Length Code | AZ | AP | AN | AS | AT |
20 | 1.31 (0.072) | 0.56 (0.030) | 0.43 (0.023) | 0.31 (0.017) | 0.19 (0.011) |
40 | 0.70 (0.038) | 0.30 (0.016) | 0.23 (0.013) | 0.17 (0.009) | 0.10 (0.006) |
Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm
Sample ΔP calculation
UR629 Series 40” length housing with F48 (3” SAE) split flange ports using AN grade media. Operating conditions 600 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ΔP= ΔP housing + ΔP element
= (0.45 x 1.2/0.9) bard (housing)
+ ((600 x 0.23/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.60 (housing) + 0.29 bard (element)
= 0.89 bard (12.9 psid)
Ordering Information
For new installations, select one complete part number from each section below
Section 1: Housing P/N: UR [Table A] [Table B] [Table C]
Note: Pall Athalon filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.Note:Z indicates fluorocarbon seals are standard. Other options are available;contact Pall. Housing P/N designates indicator port fitted with a plastic shipping plug.
Table A | Table B | Table C |
Table 1 | Tables 2, 3, 4 | Table 5 |
629C | D4820Z | A,G, or N |
D4840Z | ||
D6420Z | ||
D6440Z | ||
F4820Z | ||
F4840Z | ||
F6420Z | ||
F6440Z | ||
649C | D4840Z | A,G, or N |
D6440Z | ||
F4840Z | ||
F6440Z | ||
669C | D6440Z | A or G |
F6440Z | ||
689C | D6440Z | A or G |
F6440Z |
Table 1: No. of Filter Housings
Code | No. of Housings |
629 | 2 (1 per side) |
649 | 4 (2 per side) |
669 | 6 (3 per side) |
689 | 8 (4 per side) |
Table 2: Housing Port Options
Code | Port Style |
D | Flange J518C code 61 |
F | ISO 6162 split flange |
Table 3: Port Size
Code | Port Style |
48 | 3” nominal |
64 | 4” nominal |
Table 4: Housing Length and Seal Options
Code | Length and Seal Material |
20Z | 20” nominal length, fluorocarbon seals |
40Z | 40” nominal length, fluorocarbon seals |
Table 5: Bypass Valve and Service Options
Code | Bypass Valve and Service Type |
A | 1.7 bard (25 psid) bypass valve, cover service |
G | 4.5 bard (65 psid) bypass valve, cover service |
N | No bypass valve |
Seal Kit P/N: UR629CSKZ
*Other seal material options are available; Contact Pall.
Section 2 Element P/N: UE 610 [Table 6] [Table 3]
Note: Z indicates fluorocarbon seals are standard.
Other options are available; contact Pall.
Table 6: Filter Element Options
Code | ßx(c) ≥2000 based on ISO 16889 | CST Rating* |
AZ | 3 | 07/04/01 |
AP | 5 | 11/08/03 |
AN | 7 | 13/09/04 |
AS | 12 | 15/11/06 |
AT | 25 | 16/14/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Section 3 (At least one Differential Pressure Indicator or ‘B’ type blanking plug must be ordered for each filter tower)
Differential Pressure Indicator P/N: RC [Table 7] Z [Table 8] ZNote: If no differential pressure indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug in each filter tower.
For typical installations, only 2 indicators are required – only one housing per side requires an indicator. Replace other shipping plugs with blanking plugs.
Note :Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 7: Indicator Options
Code | Brass Option indicator |
A218M | Electrical switch (SPDT) with Hirschmann connector |
A218R | Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D | Visual indicator |
Other options are available; contact Pall.
Table 8: Indicator Pressue Setting Option
Code | Valve |
084 | For ‘A’ Valve Option – Housings (1.1 bard – 16 psid) |
091 | For ‘G’ and ‘N’ Valve Options – Housings (3.5 bard – 50 psid) |
Other setting options are available; contact Pall.
Enquire about this product
All pictures shown are for illustration purpose only. Actual product may vary. All specifications are subject to change without notice.