Differential Pressure Transducer

The RCA222 Differential Pressure (ΔP) Transducers are the latest monitoring devices for use with Pall filter assemblies. They provide continuous, reliable, real time data of filter service condition to give users increased control of their fluid system maintenance procedures.

The RCA222 ΔP transducers sense the temperature and differential pressure across an in-service filter element and transmit the reading as either a digital Modbus RTU signal, or alternatively a 4-20 mA signal which can then be interpreted as a value of remaining filter life.

The RCA222 fluid differential pressure sensor device is also available with visual LED outputs with color statuses for various warning levels.

The ‘plug and play’ transducers are designed to fit all standard Pall threaded indicator ports, for applications rated up to 450 bar.

Features

  • Provides a more automated, continuous method for monitoring filter service life. Also, detection of sudden changes in filter condition can help identify potentially damaging operating conditions, enabling the operator to take corrective action before failure occurs
  • No manual on-site checking of filter status required
  • Transducer thermal lockout (< 20 ºC) ignores signals received before normal operating temperature is reached, ensuring readings are relevant
  • Available in a range of standard differential pressures to suit the Pall filter housing bypass settings
  • Modbus output gives temperature and differential pressure as two outputs
  • Modbus units can be daisy chained together back wto a single PC / PLC

Technical Information

Maximum operating pressure: 450 bar
Pressure fatigue rating: 0-400-0 bar >1 x 106
Proof pressure: 675 bar
Burst pressure (typical): 1100 bar
Number of cycles (Mechanical): 1 x105
Operating Temperature: -25°C(-13°F) to 85°C(185°F)
Minimum Ambient Temperature: -40°C (-40°F)
IP rating: IP65 with mating connector to M12-5 to IEC 61076-2-101 socket plug assembly.
Connector: PA6, 6-M12-5 PIN to IEC 61076-2-101.
4-20 mA & Modbus: PA6, 6-M12 5 Pin
LED Option: 6-M12 4 Pin, both to IEC 61076-2-101

 

Materials of construction

Body, piston, spring retainer: Brass
Spring: Stainless Steel
Seals: Fluorocarbon
Tightening torque setting: 50-60 Nm.

 

Electrical switch ratings

24 VDC PNP Maximum load 0.4A normally open, analogue output 4-20mA.

Automatic switch reset when differential pressure is reduced.

Thermal lockout T° = 20°C (68°F) Note if T < T° Digital output 1 remains normally open, digital output 2 remains normally open and analogue output remains at 4mA.

Analogue output remains at 4mA until a minimum of 25% of differential pressure range has been exceeded (dead band).

Transducer Connection
Pin 1: 24 VCC ± 10 %
Pin 2: Analogue Output 4-20 mA
Pin 3: Digital Output 1 75 % (PNP)
Pin 4: Digital Output 2 100 % (PNP)
Pin 5: 0 VDC, Ground
Connection Modbus
Pin 1: 24 VCC ± 10 %
Pin 2: N/A
Pin 3: Modbus RTU B
Pin 4: Modbus RTU A
Pin 5: 0 VDC, Ground
Connection LED’s
Pin 1: 24 VCC ± 10 %
Pin 2: Output 2 (100 %)
Pin 3: 0 VDC, Ground
Pin 4: Output 1 (75 %)
Note: 4 Pin connector only

Enquire about this product

  • This field is for validation purposes and should be left unchanged.

All pictures shown are for illustration purpose only. Actual product may vary. All specifications are subject to change without notice.

Product Code: RCA222ZK3034

Need a solution? We’re here to help

We pride ourselves on our wide industry knowledge. We’ve got an expert team and are able to source products worldwide.

Contact Us

Petroleum, Aviation & Mining Supplies